Universal AC input |
|
|
Low leakage current ≤180 umA |
|
|
Protections: Short circuit / Overload / Over voltage |
|
|
Fixed switching frequency at 45KHz |
MPS120 120w Power Supplies
|
Model Number |
Output Voltage |
Output Amps |
Minimum Load Requirement |
Load Regulation |
Line Regulation |
Ripple and Noise |
|
3.3 Volts(DC) |
24 Amps |
0% |
±3.0% |
±1.0% |
80mV pk-pk (note 1) |
|
|
5 Volts(DC) |
22 Amps |
0% |
±3.0% |
±1.0% |
80mV pk-pk (note 1) |
|
|
12 Volts(DC) |
10 Amps |
0% |
±2.0% |
±1.0% |
100mV pk-pk (note 1) |
|
|
15 Volts(DC) |
8 Amps |
0% |
±2.0% |
±1.0% |
100mV pk-pk (note 1) |
|
|
24 Volts(DC) |
5 Amps |
0% |
±2.0% |
±1.0% |
120mV pk-pk (note 1) |
|
|
48 Volts(DC) |
2.5 Amps |
0% |
±2.0% |
±1.0% |
120mV pk-pk (note 1) |
MPS120 Single Series
|
Model Number |
Voltage Tolerance |
Over Voltage Protection |
Over Current Protection |
Rise Time |
|
±3.0% |
800mS, 20mS/230VAC / 2000mS, 50mS/115VAC |
|||
|
±3.0% |
800mS, 20mS/230VAC / 2000mS, 50mS/115VAC |
|||
|
±2.0% |
800mS, 20mS/230VAC / 2000mS, 50mS/115VAC |
|||
|
±2.0% |
120~140% Output shutdown when activated auto recover |
120~160% rated output power, auto recover |
800mS, 20mS/230VAC / 2000mS, 50mS/115VAC |
|
|
±2.0% |
120~140% Output shutdown when activated auto recover |
120~160% rated output power, auto recover |
800mS, 20mS/230VAC / 2000mS, 50mS/115VAC |
|
|
±2.0% |
120~140% Output shutdown when activated auto recover |
120~160% rated output power, auto recover |
800mS, 20mS/230VAC / 2000mS, 50mS/115VAC |
|
Input Specifications
Environmental Specifications
General Specifications
|
Output Specifications
Physical Specifications
Notes 1. Ripple and Noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47 uf parallel capacitor. 2. Tolerance: includes set up tolerance, line regulation and load regulation. 3. 33% Duty cycle max within every 30S. Average output power should not exceed the rated power. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |