MDR20 20w Power Supplies

20W Single Ouput Industrial DIN Rail Power Supply

Universal AC input

Protections: Short circuit/Overload/ Over voltage

Cooling by free air convection

Can be installed on DIN rail S-35/7.5 or 15

NEC class 2/LPS compliant

LED indicator for power on, DC OK relaty contact, No load power consumption of <0.75W

Model Number

Output Voltage

Output Amps

Load Regulation

Ripple and Noise

Over Voltage Protection

Voltage Tolerance

DC Voltage Adjust

Minimum Load Requirement

Efficiency

Power Good/Fail

MDR20-5

5 Volts(DC)

3 Amps

±1.5%

80mV pk-pk (Note 1)

5.75~6.75V Shutdown o/p, re-power

±2% (Note 2)

4.75~5.5V

0 ~ 3Amps

76%

3.75~6Volts (DC)/50mA

MDR20-12

12 Volts(DC)

1.67 Amps

± 1%

120mV pk-pk (Note 1)

13.8~16.2V Shutdown o/p, re-power

±1% (Note 2)

10.8~13.2V

0~1.67Amps

80%

9~13.5Volts (DC)/50mA

MDR20-24

24 Volts(DC)

1.34 Amps

± 1%

120mV pk-pk (Note 1)

17.25~20.25V Shutdown o/p, re-power

±1% (Note 2)

13.5~16.5V

0~1.34Amps

81%

11.5~16.5Volts (DC)/50mA

MDR20 series

Input Specifications

Input Voltage Range

90-264VAC / 120-370 Volts (DC)

Frequency Range

47 ~ 63Hz

Inrush Current

20 Amps @ 115VAC 40 Amps @ 230VAC cold start typ.

Input Current

0.55 Amps. @ 115VAC 0.35 Amps. @ 230VAC

Leakage Current

<1mA / 240VAC

General Specifications

Isolation

3000VAC

Isolation Input-Ground

1500VAC

Isolation Output-Ground

500VAC

Insulation Resistance

? 100M? @ 500VDC

Efficiency

76%

Safety Approvals

UL508 TUV EN60950-1 Approved NEC class 2/LPS compliant (24V,48Vonly)

Harmonic Current

Compliance to EN61000-3-2,-3

Power Good/Fail

3.75~6Volts(DC)/50mA

Environmental Specifications

Operating Temperature

-20°C to +70°C (See Derate Curve)

Storage Temperature

-40°C to +85°C

Working Humidity

20 to +90% RH, non cond

Storage Humidity

10 ~ 95% RH

EMI

Compliance to EN55022B (CISPR22B)

MTBF

236.9K Hrs min, MIL-HDBK-217F(25°C)

Vibration

10~500Hz, 5G10min./1cycle, period for 60min. each along X, Y, Z axes

EMS

Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, light industry level, criteria A

Output Specifications

Output Voltage

5 Volts(DC)

Output Amps

3 Amps

Load Regulation

±1.5%

Line Regulation

±1% max

Temperature Coefficient

± 0.03% / °C (0-50°C)

Ripple and Noise

80mV pk-pk (Note 1)

Over Voltage Protection

5.75~6.75V Shutdown o/p, re-power

Over Current Protection

105~160% rated output power Constant current limiting,auto recover

Voltage Tolerance

±2% (Note 2)

DC Voltage Adjust

4.75~5.5V

Minimum Load Requirement

0 ~ 3Amps

Rise Time

500ms, 30ms/230VAC 1200mS, 30mS/115VAC @ FL

Hold Up Time

50mS @ 230VAC 20mS @115VAC @ FL

Physical Specifications

Size (mm)

22.5 x 90 x 100

Size (Inches)

0.89” x 3.54 ” x 3.94 ”

Weight (g)

190g

Weight (oz)

6.702 oz

Notes

1. Ripple & Noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

2. Tolerance: includes set up tolerance , line regulation and load regulation.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.