Universal 90-264VAC Input

High Efficiency

Improved EMI Performance

3000V Isolation

Single, Dual & Triple Outputs

UL60950-1, EN60950-1 & IEC60950-1

Model Number

Output Voltage

Output Amps

Load Regulation

Line Regulation

Cross Regulation

Preset Accuracy

Ripple and Noise

EFM-5000

3.3 Volts(DC)

1.25 Amps

± 3% (20% FL)

±0.1~1%, typ

1%

100mV Pk-Pk, typ

EFM-5001

5 Volts(DC)

1 Amps

± 3% (20% FL)

±0.1~1%, typ

1%

100mV Pk-Pk, typ

EFM-5002

12 Volts(DC)

0.42 Amps

± 3% (20% FL)

±0.1~1%, typ

1%

100mV Pk-Pk, typ

EFM-5003

15 Volts(DC)

0.33 Amps

± 3% (20% FL)

±0.1~1%, typ

1%

100mV Pk-Pk, typ

EFM-5005

24 Volts(DC)

0.2 Amps

± 3% (20% FL)

±0.1~1%, typ

1%

100mV Pk-Pk, typ

EFM-5006

±12Volts(DC)

±0.21 Amps

± 3% (20% FL)

±0.3~1%, typ

NA / ±0.1

1%

100mV Pk-Pk, typ

EFM-5007

±15Volts(DC)

±0.17 Amps

± 3% (20% FL)

±0.3~1%, typ

NA / ±0.1

1%

100mV Pk-Pk, typ

EFM-5009

5±12Volts(DC)

0.53±0.1 Amps

0.2 / ±0.3% (20% FL) (note 6)

0.3/±0.1%

NA / ±0.1

1 /±5%

35mV Pk-Pk, typ

EFM-5011

5±15Volts(DC)

0.41±0.1 Amps

0.2 / ±0.3% (20% FL) (note 6)

0.3/±0.1%

NA / ±0.1

1 /±5%

35mV Pk-Pk, typ

EFM5 series

Input Specifications

Input Voltage Range

90-264 VAC

Frequency Range

47-63 Hz

Inrush Current

20A@115VAC, 40A@230VAC

Environmental Specifications

Operating Temperature

0 to +50°C (See Derate)

EMC

EN55022

Storage Temperature

-25 to +71°C *

EMI

FCC/A, VDE 0871/A , CISPRB

MTBF

180,000 Hrs, Mil Std 217, 25°C

General Specifications

Isolation

3000VAC

Isolation Input-Ground

2500VAC

Isolation Output-Ground

1000VAC

Efficiency

75%~78%, typ EFM-5009: 63% EFM-5011: 61%

Switching Frequency

100Khz, (fixed, typical)

Safety Approvals

UL60950-1, EN60950-1

Output Specifications

Output Voltage

3.3 Volts(DC)

Output Amps

1.25 Amps

Load Regulation

± 3% (20% FL)

Line Regulation

±0.1~1%, typ

Preset Accuracy

1%

Temperature Coefficient

±0.03%/°C

Ripple and Noise

100mV Pk-Pk, typ

Over Voltage Protection

Clamp

Over Temperature Protection

Latching, Auto Recov after Cooling and power restored

Short Circuit Protection

Continuous, self-recovering

Hold Up Time

30 mS, typ

DC Voltage Adjust (typ.)

±6% of FS (Primary)

Physical Specifications

Construction

Open Frame

Weight (g)

38g

Weight (oz)

1.4oz

Notes

* These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.