Order by phone: 1-800-823-8082 / +1-508-964-6300 M-F 8:30am to 5:30pm EST

DR60 60w Power Supplies

60W Single Output Industrial DIN Rail Power Supply

Universal AC Input

Protections: Short circuit/ over load / over voltage

Cooling by free air convection

Can be installed on DIN rail S-35/7.5 or 15

Isolation class 2

Model Number

Output Voltage

Output Amps

Ripple and Noise

Over Voltage Protection

Voltage Tolerance

DC Voltage Adjust

Minimum Load Requirement

Efficiency

DR-60-5

5 Volts(DC)

6.5 Amps

80mVpk-pk (Note 1)

5.75~6.75V Shut down o/p voltage, re-power

±2% 5Volts(DC) only (Note 2)

4.75~5.5V

0 ~ 6.5Amps

76%

DR-60-12

12 Volts(DC)

4.5 Amps

120mVpk-pk (Note 1)

13.8~16.2V Shut down o/p voltage, re-power

±1% 12~24Volts(DC) (Note 2)

11.1~13.2V

0 ~ 4.5Amps

82%

DR-60-15

15 Volts(DC)

4 Amps

120mVpk-pk (Note 1)

17.25~20.25V Shut down o/p voltage, re-power

±1% 12~24Volts(DC) (Note 2)

13.5~16.5V

0 ~ 4Amps

83%

DR-60-24

24 Volts(DC)

2.5 Amps

150mVpk-pk (Note 1)

27.6~32.4V Shut down o/p voltage, re-power

±1% 12~24Volts(DC) (Note 2)

21.6~26.4V

0 ~ 2.5Amps

84%

DR-60 series

Input Specifications

Input Voltage Range

90~264VAC / 124-370 Volts (DC)

Frequency Range

47 ~ 63Hz

Inrush Current

18 Amps @ 115VAC / 36 Amps @ 230VAC (Cold Start) typ.

Input Current

1.2 Amps. @ 115VAC / 0.8 Amps. @ 230VAC

Leakage Current

< 1mA / 240VAC

General Specifications

Isolation

3000VAC

Insulation Resistance

? 100M? / 500Volts(DC)

Efficiency

76%

Safety Approvals

UL60950-1 TUV EN60950-1 approved Design refer to EN50178

Harmonic Current

Compliance to EN61000-3-2,-3

Environmental Specifications

Operating Temperature

-20°C to +60°C (See Derate Curve)

Storage Temperature

-40°C to +85°C

Working Humidity

20~90% RH non condensing

Storage Humidity

10 ~ 95% RH

EMI

Compliance to EN55022B (CISPR22B)

MTBF

216.2K Hrs min, MIL-HDBK-217F(25°C )

Vibration

10~500Hz, 2G10min./1cycle, period for 60min. each along X, Y, Z axes

EMS

Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-2, EN61204-3,heavy industry level,criteria A

Output Specifications

Output Voltage

5 Volts(DC)

Output Amps

6.5 Amps

Load Regulation

± 1.0%

Line Regulation

± 1.0%

Temperature Coefficient

±0.03%/°C (0 ~ 50°C)

Ripple and Noise

80mVpk-pk (Note 1)

Over Voltage Protection

5.75~6.75V Shut down o/p voltage, re-power

Over Current Protection

105~160% rated output power Constant current limiting,auto recover

Voltage Tolerance

±2% 5Volts(DC) only (Note 2)

DC Voltage Adjust

4.75~5.5V

Minimum Load Requirement

0 ~ 6.5Amps

Rise Time

100ms, 30ms/230VAC; 200mS, 30mS/115VAC @ FL

Hold Up Time

100mS @ 230VAC; 23mS @115VAC @ FL

Physical Specifications

Size (mm)

78 x 93 x 56

Size (Inches)

3.07” x 3.66 ” x 2.20 ”

Weight (g)

300g

Weight (oz)

10.58 oz

Notes

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwith by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.