Model Number |
Output Voltage |
Output Amps |
Ripple and Noise |
Over Voltage Protection |
Voltage Tolerance |
DC Voltage Adjust |
Minimum Load Requirement |
Efficiency |
|
5 Volts(DC) |
5 Amps |
100mVpk-pk (Note 1) |
5.75~6.75V Shut off o/p voltage, auto recover |
±2%: 5Volts(DC) only (Note 2) |
4.75~5.5V |
0 ~ 5Amps |
72% |
|
|
12 Volts(DC) |
3.5 Amps |
200mVpk-pk (Note 1) |
13.8~16.2V Shut off o/p voltage, auto recover |
±1%: 12~24Volts(DC) (Note 2) |
10.8~13.2V |
0 ~3. 5Amps |
77% |
|
|
15 Volts(DC) |
2.8 Amps |
240mVpk-pk (Note 1) |
17.25~20.25V Shut off o/p voltage, auto recover |
±1%: 12~24Volts(DC) (Note 2) |
13.5~16.5V |
0 ~ 2.8Amps |
77% |
|
|
24 Volts(DC) |
2 Amps |
480Vpk-pk (Note 1) |
27.6~32.4V Shut off o/p voltage, auto recover |
±1%: 12~24Volts(DC) (Note 2) |
21.6~26.4V |
0 ~ 2Amps |
80% |
DR-45 series
|
Input Specifications
General Specifications
Environmental Specifications
|
Output Specifications
Physical Specifications
Notes 1. Ripple & Noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 2. Tolerance: includes set up tolerance , line regulation and load regulation. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. |